Acousti-Mat® CLP
Acousti-Mat® CLP provides acoustical control for concrete high rise construction.

Acousti-Mat® CLP Sound Ratings


Floor System Topping Insulation  Ceiling Susp. on Chan. Ceiling Drywall  Floor Covering Rating Test Number
6" Concrete (152 mm) Thinset with Tile
Thinset with Tile
No
No
No
No
No
No
Quarry Tile
Quarry Tile
STC 54
Delta IIC 19
NGC 5006017
NGC 7006023
8" Concrete (203 mm) 1/2" Maxxon
1/2" Maxxon
No
No
Yes
Yes
5/8" (16 mm)
5/8" (16 mm)
None
Wood
57F-IIC
60F-IIC
0677973
0677973
Bare Concrete,
No AM CLP (control)
None No Yes 5/8" (16 mm) None 42F-IIC,
62F-STC
0677973
8" Concrete (203 mm) 1/4" Level-Right
WearTop
No No No None 59F-IIC 72550
Bare Concrete,
No AM CLP (control)
None No No No None 37F-IIC 72550

Laboratory Sound Test: Delta IIC 19 per ASTM E 2179-03

F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E 989. F-STC (Field Sound Transmission Class) sound tests were performed in accordance with ASTM E 336 and E 413. Actual tests above, plus additional tests are available upon request. Acousti-Mat CLP is but one component of an effective sound control system. No sound control system is better than its weakest component. Care must be taken in the installation of components of construction to assure the ultimate designed acoustical performance.



Maxxon provides underlayment, gypcrete, gypsum concrete and other flooring underlayment products for construction, remodeling and renovation.
This site and all contents copyright © 2001-2008 MAXXON Inc. All rights reserved.

 Home | Canada | en français | en español